climatic tests, where attention is paid to the influence of climate on the material properties of construction materials
surface treatments and strength of adhesive joints
Every material used in construction is subjected to very strict quality tests. This is the purpose of the climatic test chamber, which can expose it to extreme conditions, simulate stress temperature and humidity states, or accelerate the ageing process of materials.
Parameters of the climatic test chamber
The basic parameters of the chamber interior are:
Adjustable temperature in the range from -40 °C to +100 °C at an ambient temperature of 23 °C.
Adjustable relative humidity of the environment in the range from 10 % to 85 % in the temperature range from +20 °C to +80 °C.
Solar radiation simulation — Osram 1200W/GS HMI lamp.
UV radiation simulation — built-in Osram/Radium lamp controlled via the software function of the temperature controller.
Rain simulation — by sprinkling with a nozzle with a controlled amount of water by a programmable controller via the software function of the humidity controller.
The Klokner Institute, a detached and independent workplace of the ČVUT, holds an irreplaceable position within Prague and the entire Czech Republic, especially in the context of international cooperation in research and standardization.
Contact
Klokner Institute at ČVUT in Prague, Šolínova 7 160 00 Praha 6 – Dejvice